Overall Screened Thermocouple Cable
Application
These cables are used with thermocouples for temperature measurements where hydrocarbon may be present.
Standards
Cable Construction
Construction
| Conductor |
Metal according to thermocouple type |
| Insulation |
PVC |
| Overall screen |
Aluminum/polyester tape with tinned copper drain wire |
| Aluminum/polyester tape with tinned copper drain wire |
Special PVC. Color depends on thermocouple type |
Properties
| Flame retardance |
NFC 32070 C2, IEC 60332-1-2 |
| Operating voltage |
250V |
| Operating temperature |
-20~60°C |
| Max. conductor temperature in service |
70°C |
| Chemical resistance |
Aliphatic and aromatic hydrocarbon resistance |
| Conductor Size |
No. of Pairs |
Min. O.D. (mm) |
Max. O.D. (mm) |
Approx. Weight(kg/km) |
| mm2 |
Solid or Stranding(mm) |
| 1 |
14 x 0.30 |
1 |
6.3 |
7.4 |
70 |
| 1.34 |
1 x 1.30 |
1 |
6.3 |
7.4 |
75 |
| 0.5 |
1 x 0.8 |
3 |
8.0 |
9.3 |
95 |
| 0.5 |
1 x 0.8 |
7 |
10.5 |
12.1 |
165 |
| 0.5 |
1 x 0.8 |
12 |
13.3 |
15.3 |
255 |
| 0.5 |
1 x 0.8 |
19 |
16.5 |
19.0 |
380 |
| 0.5 |
1 x 0.8 |
27 |
19.2 |
22.0 |
510 |